<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE document PUBLIC "-//Apache Software Foundation//DTD XDOC 1.0//EN"
        "http://www.apache.org/dtds/xdoc_1_0.dtd">
<!--
~ Licensed to the Apache Software Foundation (ASF) under one
~ or more contributor license agreements. See the NOTICE file
~ distributed with this work for additional information
~ regarding copyright ownership. The ASF licenses this file
~ to you under the Apache License, Version 2.0 (the
~ "License"); you may not use this file except in compliance
~ with the License. You may obtain a copy of the License at
~
~ http://www.apache.org/licenses/LICENSE-2.0
~
~ Unless required by applicable law or agreed to in writing,
~ software distributed under the License is distributed on an
~ "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY
~ KIND, either express or implied. See the License for the
~ specific language governing permissions and limitations
~ under the License.
-->
<document>
    <properties>
        <title>new document</title>
    </properties>

    <body>
        <section name="Introduction">The SMS Transport will allow send and receive
            messages in the form of SMSs used in mobile phones.Using this transport
            the users will be able to invoke webservices using a SMS and get the
            responce.SMS Transport is mainly focus on enableing SMPP protocal support
            for the Axis2 so that It can connect with a SMSC to send/receive SMS.It
            will also have a GSM implimentation that will enable users to connect a
            GSM modem and send/receive sms s using that.The configuration parameters
            will be different depend on the implimentaion that the user will be using
            (SMPP/ GSM) Follwoing up section will be discuss more details about the
            configuration ,usage and Extenting of the SMS Transport
        </section>

        <section name="Transport Listener" onclick="">
            <subsection
                    name="Configuration"><pre>&lt;transportReceiver name="sms"
                class="org.apache.axis2.transport.sms.SMSMessageReciever"&gt;</pre>In
                order to use the sms Transport Listener It must be Configured in the
                Axis2.xml.It will be having set of parameters to be configured depending
                on the implementation that a user needed.(SMPP/GSM)
                <br/>
                <p>
                    <br/>
                    Parameters Needed for the SMPP and GSM implementation are Explined
                    bellow.
                    <br/>
                    <br/>
                    <b>SMPP Configuration</b>
                </p>
                When using the SMPP
                implimentaiton It will connect with a SMSC (Short Message Service center)
                and Listening to the incomming messsages on a TCP connection.This
                implimentaion can be used when the data traffic is so high.
                <table
                        class="bodyTable">
                    <tr>
                        <th>Parameter</th>

                        <th>Required</th>

                        <th>Description</th>
                    </tr>

                    <tr>
                        <td>systemType</td>

                        <td>No</td>

                        <td>To inform the binding SMSC about the system Type That connecting
                            to it.The Default value is "cp". .Some SMSC s does not require this
                            to connect.
                        </td>
                    </tr>

                    <tr>
                        <td>systemId</td>

                        <td>Yes</td>

                        <td>The system_id parameter is used to identify an ESME (In this
                            case Axis2 )or an SMSC at bind time. An ESME system_id identifies
                            the ESME or ESME agent to the SMSC. The SMSC system_id provides an
                            identification of the SMSC to the ESME.
                        </td>
                    </tr>

                    <tr>
                        <td>
                            <em>Password</em>
                        </td>

                        <td>Yes</td>

                        <td>The password parameter is used by the SMSC to authenticate the
                            identity of the binding ESME (In this Case Axis2). The Service
                            Provider may require ESME’s to provide a password when binding to
                            the SMSC. This password is normally issued by the SMSC system
                            administrator.
                        </td>
                    </tr>

                    <tr>
                        <td>host</td>

                        <td>No</td>

                        <td>The IP address of the host that SMSC is located.The default is
                            Local host - 127.0.0.1
                        </td>
                    </tr>

                    <tr>
                        <td>port</td>

                        <td>No</td>

                        <td>The port Number that Axis2 must connect with the SMSC.The
                            Default port is 2775
                        </td>
                    </tr>

                    <tr>
                        <td>phoneNumber</td>

                        <td>No</td>

                        <td>The phone Number that Axis2 Application given from the Service
                            provider.
                        </td>
                    </tr>
                </table>
                <br/>
                <b>GSM Configuration</b>
                <br/>GSM implementation can be
                used to send receive SMS using a GSM modem connected.Its use the
                <a
                        href="http://smslib.org/">SMSLib
                </a>
                library so that all SMSLib supported
                GSM modems will be working with the GSM implimentation.This implementation
                can only be used when the Data Traffic is very low (about 6 messages per
                minute) since The Message Send / receive rate supported by GSM modems is
                normally very low.Other than Following Parameters in the table to use the
                GSMImplimentation User must specify the implementation Class of the GSM
                implementation as a Parameter
                <pre>&lt;parameter name="smsImplClass"&gt;org.apache.axis2.transport.sms.gsm.GSMImplManager&lt;/parameter&gt;</pre>
                <table class="bodyTable">
                    <tr>
                        <th>Parameter</th>

                        <th>Required</th>

                        <th>Description</th>
                    </tr>

                    <tr>
                        <td>gateway_id</td>

                        <td>Yes</td>

                        <td>Gateway id is the Id that is used to identify the device that
                            you are going to use as the gateway.
                        </td>
                    </tr>

                    <tr>
                        <td>com_port</td>

                        <td>Yes</td>

                        <td>The communication port that the device is connected.As a Example
                            in a Linux machine if the device is connected through a USB the port
                            will be some thing like "/dev/ttyUSB0"
                        </td>
                    </tr>

                    <tr>
                        <td>
                            <em>baud_rate</em>
                        </td>

                        <td>Yes</td>

                        <td>The Baud rate of the device.This can be found out by looking in
                            to device details.
                        </td>
                    </tr>

                    <tr>
                        <td>manufacturer</td>

                        <td>Yes</td>

                        <td>The Name of the Manufacturer that the device manufactured
                            by.Example manufactures are "NOKIA" , "HUAWEI"
                        </td>
                    </tr>

                    <tr>
                        <td>model</td>

                        <td>Yes</td>

                        <td>The model id of the device.</td>
                    </tr>

                    <tr>
                        <td>modem_poll_interval</td>

                        <td>No</td>

                        <td>This is the interval that the application will poll the devices
                            message storage to get the incoming messages.The default value is 5
                            seconds.
                        </td>
                    </tr>
                </table>
            </subsection>
        </section>

        <section name="TransportSender">
            <subsection name="Configuration"><pre>&lt;transportSender name="sms"
                class="org.apache.axis2.transport.sms.SMSSender"&gt;</pre>In
                order to use the sms Sender It must be Configured in the Axis2.xml.It will
                be having set of parameters to be configured depending on the
                implementation that a user needed.(SMPP/GSM)
            </subsection>
            The Configuration
            Parameters for the GSM and SMPP implimentations are same as the above
            discribed for the Transport Listender.
        </section>

        <section name="Extending SMS Transport">The SMS Transport is Designed to
            be extended to use with Other SMS implementations as well.It has two
            logical layers one is the SMS Layer which has all Axis2 dependent code and
            Other one is The Implementation layer which only contain the
            implementation logic related to the specific implimentation.So the
            Developers who need to write a another implementation can reuse the SMS
            layer and focus oly about thire implementation logic.
            <subsection
                    name="SMSMessageBuilder">SMSMessageBuilder determines the message format
                that Axis2 accepting from the incoming SMS.In the Default
                SMSMessageBuilder implementation its supported for the RPC type SMS format
                for the incoming SMS to invoke a Webservice its :<b>
                    "ServiceName":"Operation Name":
                    "Parameter_1=value_1":......:"Parameter_N=value_N"</b>.Developers can add
                another Builder to accept another formats by implementing the
                SMSMessageBuilder interface and Specifying it as a Parameter in the
                TransportListener
                <pre>&lt;parameter name="builderClass"&gt;Class Name&lt;/parameter&gt;</pre>
            </subsection>
            <subsection name="SMSMessageFormatter">SMSMessageFormatter
                formats the out put SMS Message Form the Axis2 MessageContext.Developers
                can Add a custom MessageFormatter by Implementing the SMSMessageFormatter
                interface and Specifying it as a Parameter in the TransportSender.
                <pre>&lt;parameter name="formatterClass"&gt;Class Name&lt;/parameter&gt;</pre>
            </subsection>
            <subsection
                    name="Implimentation">SMS Trasnport also allows Developers to add another
                SMS implementations to the SMS Transport.To Add a another Implementation
                It should have an Implementation manager that implements the
                SMSImplManager interface.In that Implementation Developers can add their
                custom implementation logic without worring about the Axis2
                Dependensies.To add a Implementation Manager It must be Specified as a
                parameter in Transport Receiver and sender
                <pre>&lt;parameter name="smsImplClass"&gt;Class Name&lt;/parameter&gt;</pre>
            </subsection>
        </section>